Login

Advanced search options

Microcentrifuge Biocen 22R, Orto Alresa

The picture may be different from the article and can include supply, which is not in the standard scope.

Microcentrifuge Biocen 22R, Orto Alresa

Order-No
Biocen22R
Art #:
Biocen 22R
Validity: 31.12.2021
Last Update: 14.06.2021
Microcentrifuge Biocen 22R, Orto Alresa

The Biocen 22 R can reach up to 30.034 xg , becoming the necessary tool for most demanding labs. Allows 24 microtubes of 2.2 ml, 32 of 0.2 ml and 8x15 ml, conical.

Usually microcentrifuges work with samples sensitive, valuables, or dangerous ( toxic, radioactive, infectious). Ortoalresa has built the Biocen 22 R with several advantages which allow a safe analysis, without interaction of centrifuge, as:

  • Cooling system which maintains the sample temperature at 4°C at max speed, 
    regardless of the rotor.
  • Chamber of centrifugation in stainless steel, allowing an easy disinfection on samples 
    leakages, avoiding contamination form the centrifuge.
  • Rotors with hermetic lids.
  • Accessories sterilizables.

User friendliness

  • LCD screen shown RPM/RCF (on steps 100 RPM/10xg),time, temperature (1°C steps) and braking (1 second steps).
  • Intuitive handling through start, stop, short spin and lid keys.
  • Rotor list on memory.
  • Timer count up/down, from 0 or at “set RPM/RCF” for test reproducibility.
  • Short spin key with speed adjustable.
  • Automatic rotor recognition.
  • Acceleration and braking selectable by operator.
  • 15 memories and pre-cooling program.
  • Automatic open lid.
  • Lid latch lock.
  • Microprocessor controlled.
  • Option: free or locked adjustment of RPM/RCF along the run.

Features

  • Induction motor maintenance free
  • Max. capacity 8 x 15 ml.
  • Speed, up to 30.034 xg/18.100 RPM.
  • Quiet: noise level < 60 dB.

Safety

  • Lid locking and holding.
  • Imbalance switch off.
  • Manual overriding.
  • Chamber of centrifugation in stainless steel.
  • Viewing and calibration port in the lid.
  • Several messages keep the operator informed about the device situation.
  • Guard ring between the chamber of centrifugation and the housing.
  • Lid dropping protection.

Cooling

  • Precooling program with rotor spinning and temperature selectable by operator.
  • 4°C at Max speed as higher.
  • Temperature range from -20°C (-4°F) to 40°C (104°F).
  • Temperature sensor inside the chamber, gas R 404A HFC.

Standards and EC Directives

EU Directives: 98/79/EC, 2006/95/EC, 2004/108/EC, 2011/65/EU, 2012/19/EU.
Regulation: 1005/2009 & 842/2006.
Standards: EN 61010-1, EN 61010-2-020, EN 61326-1.

more
Technical data
Refrigeration available: Yes